Software development for estimating the conversion factor (k-factor) at suitable scan areas, relating the dose length product to the effective dose
Creators
- 1. Graduate School of Health Sciences, Fujita Health University, Toyoake (Japan)
- 2. Kanazawa University, Graduate School of Medical Sciences, Division of Medical Sciences, Kanazawa (Japan)
- 3. Department of Imaging, Nagoya Kyoritsu Hospital, Nagoya (Japan)
- 4. Department of Radiology, Fujita Health University Hospital, Toyoake (Japan)
- 5. Department of Radiology, Fujita Health University School of Medicine, Toyoake (Japan)
- 6. Department of Radiology, Toyota Memorial Hospital, Toyota (Japan)
Description
We developed a k-factor-creator software (kFC) that provides the k-factor for CT examination in an arbitrary scan area. It provides the k-factor from the effective dose and dose-length product by Imaging Performance Assessment of CT scanners and CT-EXPO. To assess the reliability, we compared the kFC-evaluated k-factors with those of the International Commission on Radiological Protection (ICRP) publication 102. To confirm the utility, the effective dose determined by coronary computed tomographic angiography (CCTA) was evaluated by a phantom study and k-factor studies. In the CCTA, the effective doses were 5.28 mSv in the phantom study, 2.57 mSv (51%) in the k-factor of ICRP, and 5.26 mSv (1%) in the k-factor of the kFC. Effective doses can be determined from the kFC-evaluated k-factors in suitable scan areas. Therefore, we speculate that the flexible k-factor is useful in clinical practice, because CT examinations are performed in various scan regions. (authors)
Availability note (English)
Available from doi: http://dx.doi.org/10.1093/rpd/ncw256Additional details
Identifiers
- DOI
- 10.1093/rpd/ncw256;
Publishing Information
- Journal Title
- Radiation Protection Dosimetry
- Journal Volume
- 174
- Journal Issue
- 4
- Journal Page Range
- p. 565-574
- ISSN
- 0144-8420
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- France
- INIS RN
- 48063664
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY; S62: RADIOLOGY AND NUCLEAR MEDICINE; S97: MATHEMATICAL METHODS AND COMPUTING;
- Descriptors DEI
- BIOMEDICAL RADIOGRAPHY; COMPUTER CODES; COMPUTERIZED TOMOGRAPHY; CORONARIES; ICRP; PERFORMANCE; PHANTOMS; RADIATION DOSES; RADIATION PROTECTION; RELIABILITY
- Descriptors DEC
- ARTERIES; BLOOD VESSELS; BODY; CARDIOVASCULAR SYSTEM; DIAGNOSTIC TECHNIQUES; DOSES; INTERNATIONAL ORGANIZATIONS; MEDICINE; MOCKUP; NUCLEAR MEDICINE; ORGANS; RADIOLOGY; STRUCTURAL MODELS; TOMOGRAPHY
Optional Information
- Notes
- 23 refs.