Ion exchange separation of low boric acid concentrations from water

Description

Boric acid poisoning of the moderator of the TR-O experimental heavy water reactor was studied. The possibility is discussed of removing boric acid from heavy water by means of a strong basic anion exchanger, below the residual concentration of 0.01 mg B/l. Measurements of the usable capacities of the strong basic anion exchanger Zerollit FF showed that the penetration of boric acid during the sorption period does not exceed the value of 0.015 mg B/l. The dependence was found of capacity on the boric acid concentration in the solution. Analytical methods used to determine B in water are also described. (author)

Availability note (English)

MF available from INIS under the Report Number.

Files

8303069.pdf

Files (604.3 kB)

Name Size Download all
md5:5df3540c781f817603dc4f448a917cc1
604.3 kB Preview Download

Additional details

Additional titles

Original title (Czech)
Odstraneni nizkych koncentraci kyseliny borite z vody pomoci ionexu

Publishing Information

Imprint Pagination
18 p.
Report number
UJV--3357-R,CH