Published July 1976 | Version v1
Journal article

Bulk analyzer for grade determination of iron ore fines by backscatter of cobalt-60 gamma radiation

Creators

  • 1. CSIRO, Port Melbourne, Australia

Description

An accuracy of +-0.7 percent Fe (95 percent confidence intervals) can be achieved for bulk samples of normal production ore dried to less than 1 percent free moisture. Apart from a preliminary crushing of lumpy ores to -6-mm particle size, no elaborate sample preparation is required. Analysis time is 10 to 20 min or less, depending on the size of the scintillation detector crystal used. Provided Fe ore grade is all that is sought, the technique is competitive with routine wet chemical analysis, which is subject to large sample preparation errors

Additional details

Additional titles

Augmented title (English)
25--30 Kg sample size; 6-mm particle size; 10--20 min analysis time

Identifiers

Publishing Information

Journal Title
Analytical Chemistry
Journal Volume
48
Journal Issue
8
Series
Anal. Chem.
Journal Page Range
1155-1158
ISSN
0003-2700

Optional Information

Notes
Updated automatically by Metadata and Full-Text Enrichment Agent