Published January 2006 | Version v1
Journal article

Safety demonstration tests in HTGR (Control Rod Withdrawal Test)

  • 1. Japan Atomic Energy Agency, Oarai Research and Development Center, Oarai, Ibaraki (Japan)

Description

The HTTR (High Temperature Engineering Test Reactor), which had been developed as a helium-cooled and graphite-moderated test reactor aiming at establishment of the HTGR technology, achieved a reactor outlet coolant temperature of 950degC in April 2004. In order to upgrade the HTGR technology, control rod withdrawal tests at initial power of 30-60% rated power were conducted as safety demonstration tests in HTGR. Test results were evaluated with one channel-one temperature coefficient model and a newly developed multi-channel model using different temperature coefficients. The multi-channel model agreed better with power peak and transient behavior of tests. (T.Tanaka)

Additional details

Publishing Information

Journal Title
Koon Gakkai-Shi
Journal Volume
32
Journal Issue
1
Journal Page Range
p. 16-26
ISSN
0387-1096

Optional Information

Notes
14 refs., 34 figs., 4 tabs.