Published December 2010 | Version v1
Journal article

Application of palladium coating on group 5 metals for vacuum permeator. Possible problems and solutions

  • 1. University of Toyama, Hydrogen Isotope Research Center, Toyama (Japan)
  • 2. University of Toyama, Faculty of Human Development, Toyama (Japan)

Description

Permeation of hydrogen through Pd-Ta-Pd composite membrane was measured at 500 and 600degC to examine the feasibility of the concept to use this type of membrane as permeation window to recover tritium from liquid Pb-Li alloy. At 500degC, the permeation rate gradually decreased with increasing operation time due to surface contamination by carbon. These observations indicated that partial pressures of residual hydrocarbons in vacuum permeator have to be strictly controlled to avoid carbon deposition. Nevertheless, permeability could be restored by removal of carbon through reaction with O2 gas. At 600degC, however, permanent degradation took place due to development of open porosity in Pd layer and interdiffusion between Pd and Ta. Preparation of HfN intermediate layer between Pd and Ta hindered the porosity development and interdiffusion. (author)

Additional details

Publishing Information

Journal Title
Toyama Daigaku Suiso Doitai Kagaku Kenkyu Senta Kenkyu Hokoku
Journal Volume
29-30
Journal Page Range
p. 55-60
ISSN
1346-3675