Development of a new concept automatic frequency controller for an ultrasmall C-band linear accelerator guide
Creators
- 1. Department of Electronic Science and Engineering, Kyoto University, Kyoto Daigaku Katsura, Nishikyo-ku, Kyoto 615-8510 (Japan)
- 2. Department of Radiation Oncology and Image-applied Therapy, Kyoto University Graduate School of Medicine, 54 Shogoin Kawahara-cho, Sakyo-ku, Kyoto 606-8507 (Japan)
- 3. Medical Systems Administration Office, Mitsubishi Heavy Industries, Ltd., 2-16-5 Konan Minato-ku, Tokyo 108-8215 (Japan)
- 4. Department of Image-based Medicine, Division of Radiation Oncology, Institute of Biomedical Research and Innovation, 2-2, Minatojima-Minamimachi, Chuo-ku, Kobe 650-0047 (Japan)
- 5. Medical Systems Administration Office, Mitsubishi Heavy Industries, Ltd., 10, Oye-cho Minato-ku, Nagoya, Aichi 455-8515 (Japan)
Description
We are developing a four-dimensional, image-guided radiotherapy system with a gimbaled x-ray head. The system has pursuing irradiation capability in addition to precise irradiation capability, owing to its agile x-ray head. The moving x-ray head requires a very small C-band accelerator guide. The heat intensity of the accelerator guide is much higher than that of conventional S-band medical linear accelerators. The resonance frequency varies over almost 1.0 MHz with a thermal time constant of about 30 s. An automatic frequency controller (AFC) is employed to compensate for this variation in resonance frequency. Furthermore, we noted that fast AFC response is important for step-and-shoot intensity modulation radiotherapy (IMRT), in which the beam is turned on and off frequently. Therefore, we invented a digital AFC, based on a new concept, to provide effective compensation for the thermal characteristics of the accelerator guide and to ensure stable and optimized x-ray treatment. An important aspect of the performance of the AFC is the capture-frequency range over which the AFC can seek, lock on to, and track the resonance frequency. The conventional, analog AFC used in S-band medical linear accelerators would have a capture-frequency range of about 0.9 MHz, if applied to our accelerator guide, and would be inappropriate. Conversely, our new AFC has a capture-frequency range of 24 MHz, which is well suited to our accelerator guide. The design concept behind this new AFC has been developed and verified. A full prototype system was constructed and tested on an existing accelerator guide at the rated x-ray output (500 cGy/min) of our radiotherapy system, with a pulse-repetition frequency of 300 Hz. The AFC acquired the resonance frequency of the accelerator guide within 0.15 s after beam-on, and provided stable tracking and adjustment of the frequency of the microwave source to the resonance frequency of the accelerator guide. With a planned improvement of the initialization of the AFC it should be able to acquire the resonance frequency within 33 ms
Additional details
Identifiers
- DOI
- 10.1118/1.2752581;
Publishing Information
- Journal Title
- Medical Physics
- Journal Volume
- 34
- Journal Issue
- 8
- Journal Page Range
- p. 3243-3248
- ISSN
- 0094-2405
- CODEN
- MPHYA6
INIS
- Country of Publication
- United States
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 38104778
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- CONTROL SYSTEMS; DESIGN; FREQUENCY CONTROL; IMAGES; IRRADIATION; LINEAR ACCELERATORS; MICROWAVE RADIATION; MODULATION; PARTICLE TRACKS; RADIOTHERAPY; X RADIATION
- Descriptors DEC
- ACCELERATORS; CONTROL; ELECTROMAGNETIC RADIATION; IONIZING RADIATIONS; MEDICINE; NUCLEAR MEDICINE; RADIATIONS; RADIOLOGY; THERAPY
Optional Information
- Notes
- (c) 2007 American Association of Physicists in Medicine