Published 2011 | Version v1
Journal article

A Brazilian government external individual monitoring service: Experience since 1972

  • 1. Instituto de Radioproteca e Dosimetria, IRD, Av. Salvador Allende s/n, 22780-160 Rio de Janeiro, RJ (Brazil)

Description

Instituto de Radioproteca e Dosimetria, a Brazilian government research institute, provides individual monitoring services since 1972. Its dosemeters are: film-based thorax for whole body photons, thermoluminescence dosimetry (TLD) albedo for whole body neutrons and TLD ring for extremity photons. About 6000 radiation workers are currently being monitored with film dosemeters in 256 different facilities in Brazil, most of them working in health-related activities. Around 400 Brazilian radiation workers are monitored with TLD albedo neutron monitor and about 500 workers use TLD rings. This paper describes the monitoring systems used, presents the results obtained in internal quality programs and in intercomparison exercises and analyses the measured dose values from 1985 to 2009. (authors)

Availability note (English)

Available from doi: http://dx.doi.org/10.1093/rpd/ncq456

Additional details

Identifiers

Publishing Information

Journal Title
Radiation Protection Dosimetry
Journal Volume
144
Journal Issue
1-4
Journal Page Range
p. 130-136
ISSN
0144-8420

Conference

Title
European conference on individual monitoring of ionising radiation
Acronym
IM2010
Dates
8-12 Mar 2010
Place
Athens (Greece)

Optional Information

Notes
9 refs