Electrochemical sensors for the simultaneous determination of zinc, cadmium and lead using a Nafion/ionic liquid/graphene composite modified screen-printed carbon electrode
Creators
- 1. Electrochemistry and Optical Spectroscopy Research Unit (EOSRU), Department of Chemistry, Faculty of Science, Chulalongkorn University, 254 Phayathai Road, Patumwan, Bangkok (Thailand)
- 2. Institute of Chemistry, Department of Analytical Chemistry, Karl-Franzens University, Universitätsplatz 1, Graz A-8010 (Austria)
- 3. Department for Nanostructured Materials, Jozef Stefan Institute, Ljubljana (Slovenia)
- 4. Department of Chemistry, Faculty of Science, Srinakharinwirot University, Sukhumvit 23, Wattana, Bangkok (Thailand)
- 5. Center of Excellence on Petrochemical and Materials Technology, Chulalongkorn University, Patumwan, Bangkok (Thailand)
Description
A simple, low cost, and highly sensitive electrochemical sensor, based on a Nafion/ionic liquid/graphene composite modified screen-printed carbon electrode (N/IL/G/SPCE) was developed to determine zinc (Zn(II)), cadmium (Cd(II)), and lead (Pb(II)) simultaneously. This disposable electrode shows excellent conductivity and fast electron transfer kinetics. By in situ plating with a bismuth film (BiF), the developed electrode exhibited well-defined and separate peaks for Zn(II), Cd(II), and Pb(II) by square wave anodic stripping voltammetry (SWASV). Analytical characteristics of the BiF/N/IL/G/SPCE were explored with calibration curves which were found to be linear for Zn(II), Cd(II), and Pb(II) concentrations over the range from 0.1 to 100.0 ng L−1. With an accumulation period of 120 s detection limits of 0.09 ng mL−1, 0.06 ng L−1 and 0.08 ng L−1 were obtained for Zn(II), Cd(II) and Pb(II), respectively using the BiF/N/IL/G/SPCE sensor, calculated as 3σ value of the blank. In addition, the developed electrode displayed a good repeatability and reproducibility. The interference from other common ions associated with Zn(II), Cd(II) and Pb(II) detection could be effectively avoided. Finally, the proposed analytical procedure was applied to detect the trace metal ions in drinking water samples with satisfactory results which demonstrates the suitability of the BiF/N/IL/G/SPCE to detect heavy metals in water samples and the results agreed well with those obtained by inductively coupled plasma mass spectrometry. - Highlights: • Nafion/ionic liquid/graphene composite modified electrode was fabricated. • Simultaneous determination of Zn, Cd and Pb in real samples was studied. • Zn, Cd and Pb could be sensitively measured as low as 90, 60 and 80 pg mL−1.
Availability note (English)
Available from http://dx.doi.org/10.1016/j.aca.2016.03.026Additional details
Identifiers
- DOI
- 10.1016/j.aca.2016.03.026;
- PII
- S0003-2670(16)30343-9;
Publishing Information
- Journal Title
- Analytica Chimica Acta
- Journal Volume
- 918
- Journal Page Range
- p. 26-34
- ISSN
- 0003-2670
- CODEN
- ACACAM
INIS
- Country of Publication
- Netherlands
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 48002218
- Subject category
- S37: INORGANIC, ORGANIC, PHYSICAL AND ANALYTICAL CHEMISTRY;
- Descriptors DEI
- BISMUTH; BUILDUP; CADMIUM; COMPOSITE MATERIALS; CONCENTRATION RATIO; DRINKING WATER; ELECTROCHEMISTRY; ELECTRON TRANSFER; ELECTRONS; FILMS; GRAPHENE; ICP MASS SPECTROSCOPY; LEAD; MOLTEN SALTS; PLATING; SENSITIVITY; SENSORS; STRIPPING; VOLTAMETRY; ZINC
- Descriptors DEC
- CARBON; CHEMISTRY; DEPOSITION; DIMENSIONLESS NUMBERS; DIRECT REACTIONS; ELEMENTARY PARTICLES; ELEMENTS; FERMIONS; HYDROGEN COMPOUNDS; LEPTONS; MASS SPECTROSCOPY; MATERIALS; METALS; NONMETALS; NUCLEAR REACTIONS; OXYGEN COMPOUNDS; SALTS; SPECTROSCOPY; SURFACE COATING; TRANSFER REACTIONS; WATER
Optional Information
- Copyright
- Copyright (c) 2016 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.