The characterization of a large multi-axis ionization chamber array in a 1.5 T MRI linac
- 1. Department of Radiation Oncology, The Netherlands Cancer Institute, Plesmanlaan 121, 1066CX Amsterdam (Netherlands)
- 2. Division of Medical Physics in Radiation Oncology, German Cancer Research Center, D-69120 Heidelberg (Germany)
- 3. Department of Radiotherapy, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX, Utrecht (Netherlands)
Description
By combining magnetic resonance imaging (MRI) scanners and radiotherapy treatment units the need arises for new radiation measurement equipment that can be used in the magnetic field of the MRI. This study describes the investigation of the influence of the 1.5 T magnetic field from an MRI linac on the STARCHECKMAXI MR, a large 2D ionization chamber detector panel.
Measurements were performed on an MRI linac and a conventional linac to investigate the behaviour of the detector panel with and without the 1.5 T magnetic field. We measured reproducibility, linearity, warm-up effect, saturation/recombination and chamber orientation. A comparison with gafchromic film was performed and the effect of motion of the panel during measurements inside a magnetic field was investigated.
The reproducibility, linearity, warm-up effect, saturation/recombination show no significant deviations with or without magnetic field. An absolute difference in reading of 2.1% was found between off-axis chambers on different axes. The comparison with film shows good agreement. Spurious readings are induced while the panel is undergoing a motion in the magnetic field during measurements.
The STARCHECKMAXI MR is suited for use in a 1.5 T MRI linac. Care must be taken when comparing un-normalized profiles from different axes of the detector panel and when the panel is undergoing motion during measurements. (paper)
Availability note (English)
Available from http://dx.doi.org/10.1088/1361-6560/aae90aAdditional details
Identifiers
Publishing Information
- Journal Title
- Physics in Medicine and Biology
- Journal Volume
- 63
- Journal Issue
- 22
- Journal Page Range
- [9 p.]
- ISSN
- 0031-9155
- CODEN
- PHMBA7
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 52003171
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- FILM DOSIMETRY; IONIZATION CHAMBERS; LINEAR ACCELERATORS; MAGNETIC FIELDS; MAGNETS; NMR IMAGING; PANELS
- Descriptors DEC
- ACCELERATORS; DIAGNOSTIC TECHNIQUES; DOSIMETRY; EQUIPMENT; MEASURING INSTRUMENTS; RADIATION DETECTORS