Published January 1, 2002 | Version v1
Report

Shielding study for fast-burst reactor building

Description

A study was conducted to evaluate the radiation levels and the response of various diagnostic components in and around the building that houses the Godiva IV fast-burst reactor assembly. In a typical operation of 1 MW-s (3.6∼10f'is∼s ions) in a 50 ps fwhm burst the peak power approaches 100,000 MW. The unshielded dose at 3 m is about 500 Rem. The results will be used to evaluate the radiation levels and shielding requirements for a new facility, and to anticipate problems with new safety, security, and diagnostic instrumentation. The study was required because of the difficulty of making accurate calculations, the intensity of the radiation, the mixed neutron and gamnta-ray source terms, and the complex nature of the structure. In addition to detailed dosimetry, attention was paid to the evaluation of spurious electromagnetic and radiofrequency signals produced in detectors, cables, and conduits.

Additional details

Publishing Information

Imprint Pagination
5 p.
Report number
LA-UR--02-0121

Conference

Title
12. Biennial Radiation Protection Shielding Division Topical Meeting
Dates
14-18 Apr 2002
Place
Santa Fe, NM (United States)

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
41133932
Subject category
S07: ISOTOPES AND RADIATION SOURCES;
Resource subtype / Literary indicator
Conference, Non-conventional Literature
Descriptors DEI
CABLES; DOSIMETRY; EVALUATION; NEUTRONS; PEAK LOAD; SAFETY; SECURITY; SHIELDING
Descriptors DEC
BARYONS; ELEMENTARY PARTICLES; FERMIONS; HADRONS; NUCLEONS

Optional Information

Funding organization
US Department of Energy (United States)
Secondary number(s)
LA-UR--02-121