Coordinate detector with 2-10μm resolution on the base of charge-coupled devices
Description
The coordinate detector of ionized radiation on the base of charge-coupled devices (CCD) and concrete matrix of 288x232 cell is offered. The given analysis of amplitude and noise characteristics has shown, that the signal in CCD cell from a relativistic particle comes to approximately 103 carriers when signal ratio to noise is approximately 5 at room temperature. Detector dead time is 3.4 ms, resolution time is approximately 400 ns. The estimations of time and amplitude characteristic dependence are given, Coordinate device resolution is σ approximately 2-10 μm. Minimum resolution between tracks is approximately 100 μm. Radiation hardness of CCD is approximately 1O12 particles/CCD. Having two coordinates in the plane of CCD for every track, multitrack events can be detected with the help of the offered device
Availability note (English)
MF available from INIS under the Report Number.Files
12608464.pdf
Files
(517.4 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:cdecbb4c9f8c45cba8d99c3af36cafff
|
517.4 kB | Preview Download |
System files
(60.5 kB)
| Name | Size | Download all |
|---|
Additional details
Additional titles
- Original title (Russian)
- Координатный детектор с разрешением 2-10 мкм на основе прибора с зарядовой связью
Publishing Information
- Imprint Pagination
- 23 p.
- Report number
- IFVE-OEF--80-10
INIS
- Country of Publication
- USSR
- Country of Input or Organization
- USSR
- INIS RN
- 12608464
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Descriptors DEI
- AMPLITUDES; BACKGROUND NOISE; CHARGE-COUPLED DEVICES; DEAD TIME; DIAGRAMS; DIGITAL SYSTEMS; POSITION SENSITIVE DETECTORS; SPATIAL RESOLUTION; SPECIFICATIONS; TIME RESOLUTION
- Descriptors DEC
- INFORMATION; MEASURING INSTRUMENTS; NOISE; RADIATION DETECTORS; RESOLUTION; SEMICONDUCTOR DEVICES; TIMING PROPERTIES
Optional Information
- Notes
- 20 refs.; 7 figs.; 2 tables.