Published January 2017 | Version v1
Journal article

Moisture and salt monitoring in concrete by evanescent field dielectrometry

  • 1. ICVBC-CNR, Via Madonna del Piano 10, Sesto Fiorentino (Italy)
  • 2. CRC-LRMH Champs-sur-Marne (France)
  • 3. IFAC-CNR, Via Madonna del Piano 10, Sesto Fiorentino (Italy)

Description

Monitoring the water content and detecting the presence of soluble salts in concrete is a key issue for its maintenance. Evanescent field dielectrometry, originally developed for the diagnostics of frescoes and mural paintings, is proposed as a tool for monitoring the decay of cement-based materials. A measuring system, based on a scalar network analyzer and a resonant probe, has been realized and tested on concrete samples taken from historical buildings in France or purposely developed in the laboratory. Measurements on water-saturated and oven-dry samples provide the basis for calibrating the instrument for on site monitoring of concrete historical buildings, sculptures and cement-based artifacts. (paper)

Availability note (English)

Available from http://dx.doi.org/10.1088/1361-6501/28/1/014002

Additional details

Publishing Information

Journal Title
Measurement Science and Technology
Journal Volume
28
Journal Issue
1
Journal Page Range
[7 p.]
ISSN
0957-0233
CODEN
MSTCEP

INIS

Country of Publication
United Kingdom
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
49031980
Subject category
S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
Descriptors DEI
CEMENTS; CONCRETES; CULTURAL OBJECTS; FRANCE; HUMIDITY; MAINTENANCE; MEASURING METHODS; MONITORING; SALTS; WATER
Descriptors DEC
BUILDING MATERIALS; DEVELOPED COUNTRIES; EUROPE; HYDROGEN COMPOUNDS; MATERIALS; MOISTURE; OXYGEN COMPOUNDS; WESTERN EUROPE