Published 1984 | Version v1
Journal article

Signal to noise ratio dependence on cylindrical scintillator radius

  • 1. Tomskij Politekhnicheskij Inst. (USSR). Nauchno-Issledovatel'skij Inst. Ehlektronnoj Introskopii

Description

Signal to noise ratio dependence on the radius of cylindrical scintillator (CsI, CdWO4, plastic) of radiometric testing device, using 0.2...5 MeV photon radiation, has been studied theoretically and experimentally. Analytical expressions are obtained. Results of the theoretical and experimental studies permit to evaluate signal to noise ratio for the available dimensions of scintillators or to select the minimum dimensions of scintillator, proceeding from the required signal to noise ratio

Additional details

Additional titles

Original title (Russian)
Зависимост' отношения сигнал/шум от радиуса цилиндрического сцинтиллятора

Publishing Information

Journal Title
Defektoskopiya
Journal Issue
no.11
Series
Defektoskopiya.
ISSN
0130-3082

Optional Information

Notes