Published June 2, 2003
| Version v1
Report
Beam losses at injection energy and during acceleration in the Tevatron
Description
Protons and anti-protons circulate on helical orbits in the Tevatron. At injection energy (150 GeV) the lifetimes of both species are significantly lower on the helical orbits compared to lifetimes on the central orbit but for different reasons. There are also significant beam losses in both beams when they are accelerated to top energy (980 GeV) again for different reasons. They report on experimental studies to determine the reasons and on methods of improving the lifetimes and losses for both beams
Availability note (English)
Available FR-om PURL: https://www.osti.gov/servlets/purl/811336-eM06hS/native/Additional details
Identifiers
Publishing Information
- Imprint Pagination
- 345 Kilobytes
- Report number
- FERMILAB-Conf--03/100-T
Conference
- Title
- PAC 2003
- Dates
- 12-16 May 2003
- Place
- Portland, OR (United States)
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 34043464
- Subject category
- S43: PARTICLE ACCELERATORS;
- Resource subtype / Literary indicator
- Conference, Non-conventional Literature
- Descriptors DEI
- ANTIPROTON BEAMS; BEAM DYNAMICS; BEAM INJECTION; FERMILAB TEVATRON; GEV RANGE; ORBIT STABILITY; PROTON BEAMS
- Descriptors DEC
- ACCELERATORS; ANTINUCLEON BEAMS; ANTIPARTICLE BEAMS; BEAMS; CYCLIC ACCELERATORS; DYNAMICS; ENERGY RANGE; MECHANICS; NUCLEON BEAMS; PARTICLE BEAMS; STABILITY; SYNCHROTRONS
Optional Information
- Contract/Grant/Project number
- AC--02-76CH03000
- Funding organization
- USDOE Office of Energy Research (ER) (United States)