Motor-operated valve (MOV) actuator motor and gearbox testing
Creators
- 1. Lockheed Idaho Technologies Co., Idaho Falls, ID (United States)
Description
Researchers at the Idaho National Engineering and Environmental Laboratory tested the performance of electric motors and actuator gearboxes typical of the equipment installed on motor-operated valves used in nuclear power plants. Using a test stand that simulates valve closure loads against flow and pressure, the authors tested five electric motors (four ac and one dc) and three gearboxes at conditions a motor might experience in a power plant, including such off-normal conditions as operation at high temperature and reduced voltage. They also monitored the efficiency of the actuator gearbox. All five motors operated at or above their rated starting torque during tests at normal voltages and temperatures. For all five motors, actual torque losses due to voltage degradation were greater than the losses calculated by methods typically used for predicting motor torque at degraded voltage conditions. For the dc motor the actual torque losses due to elevated operating temperatures were greater than the losses calculated by the typical predictive method. The actual efficiencies of the actuator gearboxes were generally lower than the running efficiencies published by the manufacturer and were generally nearer the published pull-out efficiencies. Operation of the gearbox at elevated temperature did not affect the operating efficiency
Availability note (English)
Available from INIS in electronic form and/or on microfiche ; Also available from OSTI as TI97008289; NTIS; GPO.
Files
Additional details
Publishing Information
- Imprint Pagination
- 52 p.
- Report number
- NUREG/CR--6478
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 29013054
- Subject category
- S22: GENERAL STUDIES OF NUCLEAR REACTORS;
- Resource subtype / Literary indicator
- Numerical Data
- Descriptors DEI
- ACTUATORS; DESIGN BASIS ACCIDENTS; ELECTRIC MOTORS; ENGINEERED SAFETY SYSTEMS; EXPERIMENTAL DATA; GEARS; NUCLEAR POWER PLANTS; PERFORMANCE TESTING; TEMPERATURE DEPENDENCE; VALVES
- Descriptors DEC
- ACCIDENTS; CONTROL EQUIPMENT; DATA; ELECTRICAL EQUIPMENT; EQUIPMENT; FLOW REGULATORS; INFORMATION; MACHINE PARTS; MOTORS; NUCLEAR FACILITIES; NUMERICAL DATA; POWER PLANTS; REACTOR ACCIDENTS; TESTING; THERMAL POWER PLANTS
Optional Information
- Contract/Grant/Project number
- Contract AC07-94ID13223
- Funding organization
- Nuclear Regulatory Commission, Washington, DC (United States).
- Secondary number(s)
- INEL--96/0219.