Published April 2008
| Version v1
Journal article
Effect of unbalanced voltage on windings temperature, operational life and load carrying capacity of induction machine
Creators
- 1. Gdynia Maritime University, Department of Ship Electrical Power Engineering, Morska Street 83, 81-225 Gdynia (Poland)
Description
This paper investigates the influence of the CVUF angle on the windings temperature rise and the derating factor of an induction machine supplied with unbalanced voltage. The effect of simultaneous voltage unbalance and harmonics on its operational life is analyzed as well. The results of calculations and experimental investigations are presented for two induction cage machines of rated power 3 and 5.5 kW
Availability note (English)
Available from http://dx.doi.org/10.1016/j.enconman.2007.07.033Additional details
Identifiers
- DOI
- 10.1016/j.enconman.2007.07.033;
- PII
- S0196-8904(07)00240-3;
Publishing Information
- Journal Title
- Energy Conversion and Management
- Journal Volume
- 49
- Journal Issue
- 4
- Journal Page Range
- p. 761-770
- ISSN
- 0196-8904
- CODEN
- ECMADL
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 39094101
- Subject category
- S71: CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSICS;
- Descriptors DEI
- CAPACITY; ELECTRIC MOTORS; ELECTRIC POTENTIAL; HARMONICS; INDUCTION
- Descriptors DEC
- ELECTRICAL EQUIPMENT; ENGINES; EQUIPMENT; MOTORS; OSCILLATIONS