Analysis of magnetic field measurement results for the AGS booster magnets

  • 1. Brookhaven National Lab., Upton, NY (United States)

Description

Magnetic field measurements have been made on nearly 200 conventional magnets that have been installed in the AGS Booster and its associated transfer lines. The measurements were intended to monitor the quality of the magnets being produced and to check the performance of each magnet before installation. The magnetic measurements effort led to certain improvements in the manufacturing process, which then subsequently produced very good, very uniform magnets. The integrated dipole fields of the 36 booster dipoles are uniform to 1.5 parts in ten thousand. The magnetic measurements indicate that the quadrupoles were manufactured to an accuracy of 3 ten thousandths of an inch, which is better than they can physically measure

Additional details

Publishing Information

Imprint Title
Conference record of the 1991 IEEE particle accelerator conference: Accelerator science and technology. Volume 1 of 5
Imprint Pagination
689 p.
Journal Page Range
p. 45-47.
Report number
DOE/ER/40607--1-Vol.1

Conference

Title
1991 Institute of Electrical and Electronics Engineers (IEEE) particle accelerator conference (PAC).
Dates
6-11 May 1991.
Place
San Francisco, CA (United States).

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
24001828
Subject category
S43: PARTICLE ACCELERATORS;
Resource subtype / Literary indicator
Conference, Numerical Data, Non-conventional Literature
Descriptors DEI
BROOKHAVEN AGS; ERRORS; EXPERIMENTAL DATA; FABRICATION; MAGNETIC FIELDS; MAGNETS; PARTICLE BOOSTERS; PERFORMANCE TESTING; QUALITY CONTROL
Descriptors DEC
ACCELERATORS; CONTROL; CYCLIC ACCELERATORS; DATA; EQUIPMENT; INFORMATION; NUMERICAL DATA; SYNCHROTRONS; TESTING

Optional Information

Secondary number(s)
CONF-910505--Vol.1.