Published May 22, 2008
| Version v1
Journal article
Measurement of the Fermi constant by FAST
Creators
- 1. CERN, Geneva (Switzerland)
- 2. CIEMAT, Madrid (Spain)
- 3. Universite de Geneve, Geneva (Switzerland)
- 4. Paul Scherrer Institute, Villigen (Switzerland)
Description
An initial measurement of the lifetime of the positive muon to a precision of 16 parts per million (ppm) has been performed with the FAST detector at the Paul Scherrer Institute. The result is τμ=2.197083(32)(15)μs, where the first error is statistical and the second is systematic. The muon lifetime determines the Fermi constant, GF=1.166352(9)x10-5GeV-2 (8 ppm)
Availability note (English)
Available from http://dx.doi.org/10.1016/j.physletb.2008.04.006Additional details
Identifiers
- DOI
- 10.1016/j.physletb.2008.04.006;
- arXiv
- arXiv:0707.3904v2;
- PII
- S0370-2693(08)00419-X;
Publishing Information
- Journal Title
- Physics Letters. Section B
- Journal Volume
- 663
- Journal Issue
- 3
- Journal Page Range
- p. 172-180
- ISSN
- 0370-2693
- CODEN
- PYLBAJ
INIS
- Country of Publication
- Netherlands
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 40046856
- Subject category
- S72: PHYSICS OF ELEMENTARY PARTICLES AND FIELDS;
- Descriptors DEI
- ACCURACY; ERRORS; FERMI INTERACTIONS; LIFETIME; MUONS PLUS
- Descriptors DEC
- ANTILEPTONS; ANTIMATTER; ANTIPARTICLES; BASIC INTERACTIONS; ELEMENTARY PARTICLES; FERMIONS; INTERACTIONS; LEPTONS; MATTER; MUONS; WEAK INTERACTIONS
Optional Information
- Copyright
- Copyright (c) 2008 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.