Published March 1, 2016 | Version v1
Journal article

Dosimetry verification on VMAT and IMRT radiotherapy techniques: In the case of prostate cancer

  • 1. Physic Department, Faculty of Mathematics and Natural Science, Universitas Indonesia (Indonesia)

Description

Radiotherapy treatment depends on the accuracy of the dose delivery to patients, the purpose of the study is to verify the dose in IMRT and VMAT technique in prostate cancer cases correspond to TPS dose using phantom base on ICRU No.50. The dose verification of the target and OAR was performed by placing the TLD Rod LiF100 and EBT2 Gafchromic film at slab hole of pelvic part of the Alderson RANDO phantom for prostate cancer simulation. The Exposed TLDs was evaluated using the TLD Reader Harshaw while EBT2 film was scanned using Epson scanner. The point dose measurements were compared between planned dose and measured dose at target volume and OAR. The result is the dose difference at target volume, bladder and rectum for IMRT and VMAT are less than 5%. On the other hand, the dose difference at the Femoral head is more than 5% for both techniques because the location of OAR already in low gradient dose. Furthermore, the difference dose of the target volume for IMRT technique tends to be smaller than VMAT either for TLD and EBT2 film detectors. From the measurement showed that the delivered dose on the phantom simulation match with ICRU No.50 criteria. (paper)

Availability note (English)

Available from http://dx.doi.org/10.1088/1742-6596/694/1/012010

Additional details

Publishing Information

Journal Title
Journal of Physics. Conference Series (Online)
Journal Volume
694
Journal Issue
1
Journal Page Range
[5 p.]
ISSN
1742-6596

Conference

Title
13. South-East Asian congress of medical physics (SEACOMP) 2015
Dates
10-12 Dec 2015
Place
Yogyakarta (Indonesia)

INIS

Country of Publication
United Kingdom
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
47117975
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Resource subtype / Literary indicator
Conference
Descriptors DEI
ACCURACY; BLADDER; COMPARATIVE EVALUATIONS; DOSIMETRY; FILMS; HANDS; HEAD; ICRU; NEOPLASMS; PATIENTS; PHANTOMS; PROSTATE; RADIATION DOSES; RADIOTHERAPY; RECTUM; SIMULATION; VERIFICATION
Descriptors DEC
ARMS; BODY; DIGESTIVE SYSTEM; DISEASES; DOSES; EVALUATION; GASTROINTESTINAL TRACT; GLANDS; INTERNATIONAL ORGANIZATIONS; INTESTINES; LARGE INTESTINE; LIMBS; MALE GENITALS; MEDICINE; MOCKUP; NUCLEAR MEDICINE; ORGANS; RADIOLOGY; STRUCTURAL MODELS; THERAPY; URINARY TRACT