Experimental and simulation study of multichannel air gap membrane distillation process with two types of solar collectors
- 1. Smart Structures Laboratory, University Ain Temouchent Belhadj Bouchaib, 46000 Ain-Temouchent (Algeria)
- 2. University of Science and Technology, Materials Science Program, Zewail City of Science and Technology, October Gardens, 6th of October, Giza 12578 (Egypt)
- 3. Department of Chemical Engineering, Faculty of Engineering, Port Said University, Port Said, 42526 (Egypt)
- 4. Department of Mechanical Power Engineering, Faculty of Engineering, Port Said University, Port Said, 42526 (Egypt)
Description
Highlights: • Desalination plant was powered by solar energy. • Solar powered membrane-based shows remarkable reducing in carbon dioxide emissions. • The solar desalination systems were numerically simulated. • Significant reduction in fresh water cost using solar membrane distillation. Solar thermal energy for membrane distillation desalination is a green and safe way for areas where water scarcity and solar irradiance are strongly correlated. In this paper, a commercial-scale of desalination plant was installed and tested to study the performance of a multichannel spiral-wound air gap membrane distillation module with an area of 14.4 m2. Air gap membrane distillation desalination plant at Port Said university was powered by solar energy using flat plate and evacuated tube collectors. The model validation was carried out. The solar desalination systems were numerically simulated using the program TRNSYS under different weather conditions throughout the year. The influence of the main operating parameters (feed flow rate and inlet temperatures of evaporator and condenser) was investigated. Regression analysis agreed with experimental data fitting using a quadratic polynomial model with coefficients of determination (R2) values of 0.997, 0.972, and 0.999 for permeate flux, outlet feed temperature, and outlet coolant temperature, respectively. The results showed that the permeate flux of the air gap membrane distillation with the evacuated tube collectors was 18.81%–30.44% higher than flat plate collector, and its cost was 22.48% lower. The specific thermal energy consumption of the air gap membrane distillation system ranged from 158.83 kWh/m3 to 346.55 kWh/m3. The maximum gain output ratio reaches 4.4 at 52 °C, depending on the feed inlet temperature. The thermal efficiency of the air gap membrane distillation system is 72%. The proposed air gap membrane distillation system produced 28.78 m3/year of fresh drinking water at a cost of USD 14.73/m3 with remarkable reducing in carbon dioxide emissions by 7,274.45 kg/year.
Availability note (English)
Available from http://dx.doi.org/10.1016/j.enconman.2021.114431Additional details
Identifiers
- DOI
- 10.1016/j.enconman.2021.114431;
- PII
- S0196890421006075;
Publishing Information
- Journal Title
- Energy Conversion and Management
- Journal Volume
- 243
- Journal Page Range
- vp.
- ISSN
- 0196-8904
- CODEN
- ECMADL
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 54031237
- Subject category
- S14: SOLAR ENERGY; S36: MATERIALS SCIENCE;
- Descriptors DEI
- CARBON DIOXIDE; COMPUTERIZED SIMULATION; DESALINATION; DESALINATION PLANTS; ENERGY CONSUMPTION; EVACUATED TUBE COLLECTORS; EVAPORATORS; FLAT PLATE COLLECTORS; FLOW RATE; HEAT EXCHANGERS; MEMBRANES; RADIANT FLUX DENSITY; REGRESSION ANALYSIS; SOLAR ENERGY; THERMAL EFFICIENCY; VAPOR CONDENSERS
- Descriptors DEC
- CARBON COMPOUNDS; CARBON OXIDES; CHALCOGENIDES; DEMINERALIZATION; EFFICIENCY; ENERGY; ENERGY SOURCES; EQUIPMENT; EVACUATED COLLECTORS; FLUX DENSITY; INDUSTRIAL PLANTS; MATHEMATICS; OXIDES; OXYGEN COMPOUNDS; RENEWABLE ENERGY SOURCES; SEPARATION PROCESSES; SIMULATION; SOLAR COLLECTORS; SOLAR EQUIPMENT; STATISTICS
Optional Information
- Copyright
- Copyright (c) 2021 Elsevier Ltd. All rights reserved.