A target for operation with hydrogen isotopes at pressures up to 1500 atm in the temperature range from 20.4 to 300 K

  • 1. Joint Inst. for Nuclear Research, Dubna (USSR). Lab. of Nuclear Problems
  • 2. AN Ukrainskoj SSR, Kiev. Inst. Geokhimii i Fiziki Mineralov

Description

To investigate mesoatomic and mesomolecular processes in mixture of hydrogen isotopes, a facility consisting of a gas target, a high pressure valve and a cryostat has been designed and made. The facility allows working with high pure hydrogen isotopes (total amount of impurities dose not exceed 10-5%) at pressures up to 1500 atm in the temperature range from 20.4 to 300 K

Files

19068436.pdf

Files (174.3 kB)

Name Size Download all
md5:2734d9ce26708a96d6875b8ec530d55a
174.3 kB Preview Download

Additional details

Additional titles

Original title (Russian)
Mishen' dlya raboty s izotopami vodoroda pri davleniyakh do 1500 at v diapazone temperatur ot 20.4 do 300 K

Publishing Information

Imprint Pagination
6 p.
Report number
JINR--13-87-704

INIS

Country of Publication
USSR
Country of Input or Organization
USSR
INIS RN
19068436
Subject category
S43: PARTICLE ACCELERATORS;
Descriptors DEI
CRYOSTATS; DIAGRAMS; HYDROGEN ISOTOPES; LOW TEMPERATURE; TARGET CHAMBERS; VALVES; VERY HIGH PRESSURE; VERY LOW TEMPERATURE
Descriptors DEC
ACCELERATOR FACILITIES; CONTROL EQUIPMENT; EQUIPMENT; FLOW REGULATORS; INFORMATION; THERMOSTATS

Optional Information

Notes
6 refs.; 3 figs.; submitted to the journal Prib. Tekh. Ehksp.