Published 1987
| Version v1
Report
Open
A target for operation with hydrogen isotopes at pressures up to 1500 atm in the temperature range from 20.4 to 300 K
Creators
- 1. Joint Inst. for Nuclear Research, Dubna (USSR). Lab. of Nuclear Problems
- 2. AN Ukrainskoj SSR, Kiev. Inst. Geokhimii i Fiziki Mineralov
Description
To investigate mesoatomic and mesomolecular processes in mixture of hydrogen isotopes, a facility consisting of a gas target, a high pressure valve and a cryostat has been designed and made. The facility allows working with high pure hydrogen isotopes (total amount of impurities dose not exceed 10-5%) at pressures up to 1500 atm in the temperature range from 20.4 to 300 K
Files
19068436.pdf
Files
(174.3 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:2734d9ce26708a96d6875b8ec530d55a
|
174.3 kB | Preview Download |
Additional details
Additional titles
- Original title (Russian)
- Mishen' dlya raboty s izotopami vodoroda pri davleniyakh do 1500 at v diapazone temperatur ot 20.4 do 300 K
Publishing Information
- Imprint Pagination
- 6 p.
- Report number
- JINR--13-87-704
INIS
- Country of Publication
- USSR
- Country of Input or Organization
- USSR
- INIS RN
- 19068436
- Subject category
- S43: PARTICLE ACCELERATORS;
- Descriptors DEI
- CRYOSTATS; DIAGRAMS; HYDROGEN ISOTOPES; LOW TEMPERATURE; TARGET CHAMBERS; VALVES; VERY HIGH PRESSURE; VERY LOW TEMPERATURE
- Descriptors DEC
- ACCELERATOR FACILITIES; CONTROL EQUIPMENT; EQUIPMENT; FLOW REGULATORS; INFORMATION; THERMOSTATS
Optional Information
- Notes
- 6 refs.; 3 figs.; submitted to the journal Prib. Tekh. Ehksp.