Published December 1972
| Version v1
Journal article
Beam current and position monitor for the Astron accelerator
Creators
Description
A beam current and position monitoring system very similar to one developed for the Berkeley ERA accelerator has been developed for use on the Astron accelerator. Beam current measurements are accurate to less than 2%. At beam currents above 500 A beam displacements less than 1 mm off-axis can be observed. The beam current and position at any two of 30 locations in the accelerator and transport section can be simultaneously monitored on either of two oscillograph systems. The current sensors do not interfere with the beam propagation and are outside the vacuum system for easy maintenance and calibration.
Additional details
Identifiers
- DOI
- 10.1063/1.1685566;
Publishing Information
- Journal Title
- Review of Scientific Instruments
- Journal Volume
- 43
- Journal Issue
- 12
- Series
- Rev. Sci. Instrum.
- Journal Page Range
- 1789-1792
- ISSN
- 0034-6748
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 4061254
- Subject category
- S43: PARTICLE ACCELERATORS;
- Descriptors DEI
- BEAM CURRENTS; BEAM MONITORING; BEAM POSITION; ELECTRON BEAMS; INDUCTION; LINEAR ACCELERATORS
- Descriptors DEC
- ACCELERATORS; BEAMS; CURRENTS; CYCLIC ACCELERATORS; LEPTON BEAMS; MONITORING; PARTICLE BEAMS
Optional Information
- Notes
- Updated automatically by Metadata and Full-Text Enrichment Agent