Quantitative in-situ analysis of impurity elements in primary aluminum processing using laser-induced breakdown spectroscopy
Creators
- 1. DT-Equipment ehf., Arleynir 2-8, 112 Reykjavik (Iceland)
- 2. Innovation Center Iceland, Arleynir 2-8, 112 Reykjavik (Iceland)
- 3. Nordural ehf., Grundartangi, 301 Akranes (Iceland)
Description
Highlights: • LIBS is suitable for on-line analysis of trace elements in molten aluminum. • For many elements, LIBS precision is comparable to laboratory OES analysis. • LOQ of 10 ppm or below has been realized in an industrial setting. • LIBS enables real-time analysis of molten aluminum during processing. -- Abstract: We report the application of laser-induced breakdown spectroscopy (LIBS) for on-line chemical analysis in a primary aluminum smelter. Measurements were performed for fourteen trace elements (Fe,Si,Cu,Ni,Ti,Cr,Mn,Sn,V,Ga,Zn,Sb,Mg,Na) and correlated with laboratory measurements on corresponding solid samples. Real-time quantification of trace elements down to ppm levels directly in the molten aluminum has been demonstrated for a number of elements (Cu,Cr,Mn,Sn). For elements Fe and Si, typically present in elevated concentrations in primary aluminum (approximately 1000 ppm and 300 ppm, respectively, in the present work) the average difference between concentration measurement carried out on the melt and laboratory results was found to be within 2.5% and 5% of the measured concentration, respectively. The observed differences can be partly related to uncertainties in the reference laboratory measurements, originating from the process of casting of solid samples from the melt. For elements with the highest vapor pressure, comparison with laboratory results on manually collected samples is shown to be less adequate. Nevertheless, we show that LIBS can provide reliable real-time measurements of the relative concentration of volatile elements, e.g., down to ppm levels in the case of Na. We conclude that for many technically important trace elements in primary aluminum, automated LIBS analysis on the molten metal is fully competitive with off-line laboratory analysis of solid process samples in terms of accuracy and precision, in addition to improving worker safety and providing significantly faster measurement results.
Additional details
Identifiers
- DOI
- 10.1016/j.sab.2019.105646;
- PII
- S0584854719302599;
Publishing Information
- Journal Title
- Spectrochimica Acta. Part B, Atomic Spectroscopy
- Journal Volume
- 158
- Journal Page Range
- vp.
- ISSN
- 0584-8547
- CODEN
- SAASBH
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 55050073
- Subject category
- S74: ATOMIC AND MOLECULAR PHYSICS;
- Descriptors DEI
- ALUMINIUM; CASTINGS; CHEMICAL ANALYSIS; LASERS; PROCESS CONTROL; SMELTERS; SPECTROSCOPY; TIME MEASUREMENT; TRACE AMOUNTS; VAPOR PRESSURE
- Descriptors DEC
- CONTROL; ELEMENTS; FURNACES; METALS; PHYSICAL PROPERTIES; THERMODYNAMIC PROPERTIES
Optional Information
- Copyright
- Copyright (c) 2019 Elsevier B.V. All rights reserved.