Published February 2013 | Version v1
Journal article

Static Structural Analysis for a Neutron Shielding Block in ITER

  • 1. Institute of the Plasma Physics, Chineses Academy of Science, Hefei 230031 (China)
  • 2. ITER Organization, 13108 St. Paul lez Durance (France)
  • 3. School of Mechanical Engineering, Anhui University of Science and Technology, Huainan 232001 (China)

Description

The ITER neutron shielding blocks are located between the outer shell and the inner shell of the vacuum vessel to provide neutron shielding. Considering the combined loads acting on the shielding blocks during ITER plasma operation, the structure of the shielding blocks must be evaluated. Using the finite element method with ANSYS analysis software, static structural analysis is performed, including elastic analysis and limit analysis for one typical shielding block. The evaluated results based on RCC-MR code show that the structure of this shielding block can meet the design requirement. (fusion engineering)

Availability note (English)

Available from http://dx.doi.org/10.1088/1009-0630/15/2/13

Additional details

Identifiers

Publishing Information

Journal Title
Plasma Science and Technology
Journal Volume
15
Journal Issue
2
Journal Page Range
p. 142-147