Published September 2009 | Version v1
Miscellaneous Open

Radiation protection of medical staff: a coordinated action by EURADOS on extremely dosimetry and the use of active personnel dosemeters (CONRAD)

Description

Monitoring of workers constitutes an integral part of any radiological protection program. However, unresolved issues in radiation protection of medical staff still remain. Research and establishment of guidelines are necessary on a variety of issues such as extremity dosimetry (fingers, eye lenses, etc), the use of double dosimetry above and below lead aprons, or the use of electronic personal dosimeters in interventional procedures. Medical practices are also evolving fast, and new techniques with ionising radiation emerge very regularly, thus implying the need of radiation protection measures for medical staff, and the implementation of new monitoring programs. In some medical applications of radiation there is an increased risk of high local exposures because of direct handling of sources or the use of beta-emitters. However, despite the large number of workers that are exposed in the medical field worldwide, only few measurements of extremity doses have been reported in the literature. Some activities of EURADOS Working Group 9 (WG9) were sponsored by the European Commission in the CONRAD project. This CONRAD project was aiming at the coordination of research on radiation protection at the workplace. Working group 9 has been involved in the coordination and promotion of European research in the field of Radiation Protection Dosimetry for Medical Staff. One of the objectives of this working group was to formulate the state of the art and to identify areas in which improvements were needed. For some of these medical applications the skin of the fingers is the limiting organ from the point of view of individual monitoring of external radiation. The wide variety of radiation field characteristics in a medical environment, and the difficulty of measuring a local dose that is representative for the maximum skin dose (usually with one single detector), makes it difficult to perform extremity dosimetry with an accuracy similar to whole-body dosimetry. Therefore a subgroup of WG9 dealt specifically with the use of extremity dosemeters in medical radiation fields. Active personal dosimeters (APDs) are very efficient tools to monitor occupational doses in real time during exposure and provide selectable alarm levels to avoid high doses. Interventional radiology operators belong to a specific worker category, which would benefit from a real time, accurate assessment of their dose. Another subgroup dealt with the adequate dosimetry of scattered photons, using APDs. They must be able to respond to low-energy (10-100 keV) and pulsed radiation with relatively high instantaneous dose rates

Files

40100128.pdf

Files (77.8 kB)

Name Size Download all
md5:7f8c6922e18ca920c00e6c729df4ac84
77.8 kB Preview Download
Part of:
Scientific Report 2007

Additional details

Identifiers

Publishing Information

Publisher
Belgian Nuclear Research Center SCK-CEN
Imprint Place
Mol (Belgium)
Imprint Title
Scientific Report 2007
Imprint Pagination
134 p.
Journal Page Range
p. 62-63
Report number
INIS-BE--0012

INIS

Country of Publication
Belgium
Country of Input or Organization
Belgium
INIS RN
40100128
Subject category
S61: RADIATION PROTECTION AND DOSIMETRY;
Resource subtype / Literary indicator
Progress Report
Descriptors DEI
ALARA; BELGIUM; DIAGNOSIS; MEDICAL EXAMINATIONS; PERSONNEL; PROGRESS REPORT; RADIATION PROTECTION; RADIOLOGY
Descriptors DEC
DEVELOPED COUNTRIES; DOCUMENT TYPES; EUROPE; MEDICAL SURVEILLANCE; MEDICINE; NUCLEAR MEDICINE; WESTERN EUROPE

Optional Information

Notes
The abstract is a contribution to the 2007 Scientific Report of the Belgian Nuclear Research Centre SCK-CEN