Published 1985
| Version v1
Journal article
Integral (effective) and differential linear coefficients of X-ray bremsstrahlung attenuation and effective build up factors of scattered radiation
Creators
Description
Computer calculations of the values of integral (effective) and differential linear factors of X-ray bremsstrahlung attenuation for radiation flaw detection were conducted. The values of effective build up factors of scattered radiation were calculated as well. Calculations were conducted in geometry of ''narrow'' beam in 20-400 kV range of tube voltage for Mg, Al, Ti, Fe base alloys of 1-500 mm thickness. Calculation data are tabulated
Additional details
Additional titles
- Original title (Russian)
- Интегральные (эффективные) и дифференциальные линейные коэффициенты ослабления тормозного рентгеновского излучения и эффективные факторы накопления рассеянного излучения
Publishing Information
- Journal Title
- Defektoskopiya
- Journal Issue
- no.1
- Series
- Defektoskopiya.
- ISSN
- 0130-3082
INIS
- Country of Publication
- Russian Federation
- Country of Input or Organization
- USSR
- INIS RN
- 16050446
- Subject category
- S07: ISOTOPES AND RADIATION SOURCES;
- Descriptors DEI
- ALUMINIUM ALLOYS; ATTENUATION; BREMSSTRAHLUNG; BUILDUP; COMPUTER CALCULATIONS; ELECTRIC POTENTIAL; INDUSTRIAL RADIOGRAPHY; IRON ALLOYS; KEV RANGE 100-1000; MAGNESIUM ALLOYS; SCATTERING; THICKNESS; TITANIUM ALLOYS; X-RAY RADIOGRAPHY
- Descriptors DEC
- ALLOYS; DIMENSIONS; ELECTROMAGNETIC RADIATION; ENERGY RANGE; KEV RANGE; MATERIALS TESTING; NONDESTRUCTIVE TESTING; RADIATIONS; TESTING
Optional Information
- Notes
- For English translation see the journal Soviet Journal of Nondestructive Testing (USA).