Obtaining Samples Representative of Contaminant Distribution in an Aquifer

  • 1. BATTELLE PACIFIC NW LAB (United States)
  • 2. American Nuclear Society (United States)

Description

Historically, groundwater samples collected from monitoring wells have been assumed to provide average indications of contaminant concentrations within the aquifer over the well-screen interval. In-well flow circulation, heterogeneity in the surrounding aquifer, and the sampling method utilized, however, can significantly impact the representativeness of samples as contaminant indicators of actual conditions within the surrounding aquifer. This paper identifies the need and approaches essential for providing cost-effective and technically meaningful groundwater-monitoring results. Proper design of the well screen interval is critical. An accurate understanding of ambient (non-pumping) flow conditions within the monitoring well is essential for determining the contaminant distribution within the aquifer. The ambient in-well flow velocity, flow direction and volumetric flux rate are key to this understanding. Not only do the ambient flow conditions need to be identified for preferential flow zones, but also the probable changes that will be imposed under dynamic conditions that occur during groundwater sampling. Once the in-well flow conditions are understood, effective sampling can be conducted to obtain representative samples for specific depth zones or zones of interest. The question of sample representativeness has become an important issue as waste minimization techniques such as low flow purging and sampling are implemented to combat the increasing cost of well purging and sampling at many hazardous waste sites. Several technical approaches (e.g., well tracer techniques and flowmeter surveys) can be used to determine in-well flow conditions, and these are discussed with respect to both their usefulness and limitations. Proper fluid extraction methods using minimal, (low) volume and no purge sampling methods that are used to obtain representative samples of aquifer conditions are presented

Availability note (English)

Available from 2002 CD-ROM; American Nuclear Society, La Grange Park, United States.

Additional details

Publishing Information

Imprint Pagination
[vp.]
Report number
PNNL-SA--36585

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
35028312
Subject category
S12: MANAGEMENT OF RADIOACTIVE WASTES, AND NON-RADIOACTIVE WASTES FROM NUCLEAR FACILITIES;
Resource subtype / Literary indicator
Non-conventional Literature
Descriptors DEI
AQUIFERS; DESIGN; DISTRIBUTION; FLOWMETERS; MINIMIZATION; MONITORING; SAMPLING; SCREENS; TRACER TECHNIQUES; VELOCITY; WASTE MANAGEMENT; WASTES
Descriptors DEC
ISOTOPE APPLICATIONS; MANAGEMENT; MEASURING INSTRUMENTS; METERS; OPTIMIZATION

Optional Information

Contract/Grant/Project number
AC06-76RL01830
Notes
Spectrum 2002, Exploring Science-Based Solutions and Technologies, 9th Biennial International Conference on Nuclear and Hazardous Waste Management
Funding organization
US Department of Energy (United States)