Published June 1969 | Version v1
Report Open

Vanadium Beta Emission Detectors for Reactor In-Core Neutron Monitoring

Description

In-core flux measurements are becoming increasingly important in both power reactors and test reactors. In particular power distribution measurements in large power reactors have to be performed with a great number of neutron detectors capable of withstanding high integrated flux values. This report presents a summary of the development and application of a new type of nuclear radiation sensor, a beta emission detector, for measurements at high neutron flux levels. The work has been carried out at the Section for Instrumentation and has been the basis for a type of neutron detector employed in the Marviken in-core system as well as for other types. The report describes the design and principle of operation, experiments and tests. Also included are the results and comments from a long-term irradiation of some detectors in the Halden reactor

Availability note (English)

Available from INIS in electronic form

Files

38115032.pdf

Files (989.9 kB)

Name Size Download all
md5:87351796419c8c0ed3cd63d90d90b586
989.9 kB Preview Download

Additional details

Publishing Information

Imprint Pagination
30 p.
Report number
AE--359

Optional Information

Notes
5 refs., 6 figs., 6 tabs.