Published March 2001 | Version v1
Journal article

Isotope effects in thermal release of H and D implanted into WC layers on graphite

Description

Thermal release of H and D implanted into WC layers graphite with 5 keV H2+ and 5 keV D2+ ions has been measured by means of the elastic recoil detection technique. It has been found that the thermal release on isochronal annealing takes place in three stages: the two stages at the lower temperature take place from the two trapping sites in the WC crystallites, and the last stage at the higher temperature from graphite phase segregated in grain boundaries of the WC layers. The isothermal release from the graphite phase has been measured at different temperatures at 350, 450, and 550 deg. C, for H and 450, 550 and 650 deg. C for D, respectively. The isothermal release data have been analyzed by using the mass balance equations and the rate constants involved have been determined by fitting their solution to the experimental data. The thermal desorption spectrum has been theoretically calculated from the solution of the mass balance equations. It has been also found that the calculated thermal desorption spectrum agrees excellently well with the experimental one obtained by Wang et al. in IPP Garching

Additional details

Identifiers

PII
S0022311500006413;

Publishing Information

Journal Title
Journal of Nuclear Materials
Journal Volume
290-293
Journal Issue
2-3
Journal Page Range
p. 428-432
ISSN
0022-3115
CODEN
JNUMAM

Optional Information

Copyright
Copyright (c) 2001 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.