The prognostic value of ultra low-dose thallium myocardial perfusion protocol using CZT SPECT
Creators
- 1. St. Ann's University Hospital, Masaryk University, Department of Internal Medicine/Cardiology (Czech Republic)
- 2. St. Ann's University Hospital, International Clinical Research Center (Czech Republic)
- 3. Masaryk University, Department of Pathological Physiology, Faculty of Medicine (Czech Republic)
Description
The purpose of this study was to assess the prognostic value of ultra-low dose thallium myocardial perfusion imaging. Three hundred and sixty-six patients (245 men) underwent ultra-low dose stress-redistribution imaging on CZT SPECT camera GE Discovery NM 530c. The stress test was performed by bicycle ergometry or regadenoson injection. The activity of 0.5 MBq (0.014 mCi) Tl-201 chloride per kilogram of body weight was administered. The stress images were acquired immediately and redistribution images were taken after 3 h. Patient follow-up was focused on combined end-point (death, myocardial infarction, unstable angina, revascularization and hospitalization for heart failure). Data analysis was performed from hospital database, with a mean period 23 months. Patients with revascularization within 1 month after SPECT was excluded as revascularization for diagnosis. Ischaemia on SPECT was found in 72 patients, 294 patients were without ischaemia. In patients with ischaemia there were 21 (29.2%) subjects with cardiac events, and 23 (7.9%) in patients without ischaemia (HR 4.15, 95% CI 2.30–7.51, p < 0.0001). Ultra-low dose thallium perfusion imaging using CZT camera provides very good prognostic results in assessment of myocardial ischaemia.
Additional details
Identifiers
Publishing Information
- Journal Title
- International Journal of Cardiovascular Imaging
- Journal Volume
- 35
- Journal Issue
- 6
- Journal Page Range
- p. 1163-1167
- ISSN
- 1569-5794
INIS
- Country of Publication
- Netherlands
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 51105019
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- BICYCLES; CDZNTE SEMICONDUCTOR DETECTORS; DATA ANALYSIS; DIAGNOSIS; HEART FAILURE; MEN; MYOCARDIAL INFARCTION; PATIENTS; SINGLE PHOTON EMISSION COMPUTED TOMOGRAPHY; THALLIUM; THALLIUM 201
- Descriptors DEC
- ANIMALS; BETA DECAY RADIOISOTOPES; CARDIOVASCULAR DISEASES; COMPUTERIZED TOMOGRAPHY; DATA PROCESSING; DAYS LIVING RADIOISOTOPES; DIAGNOSTIC TECHNIQUES; DISEASES; ELECTRON CAPTURE RADIOISOTOPES; ELEMENTS; EMISSION COMPUTED TOMOGRAPHY; HEAVY NUCLEI; ISOMERIC TRANSITION ISOTOPES; ISOTOPES; MALES; MAMMALS; MAN; MEASURING INSTRUMENTS; METALS; NUCLEI; ODD-EVEN NUCLEI; PRIMATES; PROCESSING; RADIATION DETECTORS; RADIOISOTOPES; SEMICONDUCTOR DETECTORS; SYMPTOMS; THALLIUM ISOTOPES; TOMOGRAPHY; VEHICLES; VERTEBRATES
Optional Information
- Copyright
- Copyright (c) 2019 Springer Nature B.V.