Description
This study was centered on two axes: the first is the comparative evaluation of image quality of various numerical radiology system, the second is the quality control and the optimization of protection against radiation. The publication of directive 97/43 Euratom from council of June 30, 1997 and consequently, the decree of February 12, 2004 founded a strict lawful framework that is engaged to respect the University Hospital of Amiens by the installation of a operational dosimetry system and the application of February 12, 2004 decree. (author)
Abstract (French)
Cette etude a ete centre sur deux axes principaux: le premier est l'evaluation comparative de la qualite image de differents systemes de radiologie numerique, le second est le controle qualite et l'optimisation de la radioprotection. La parution de la directive 97/43 EURATOM du conseil du 30 juin 1997 et par suite, l'arrete du 12 fevrier 2004 ont instaure un cadre reglementaire stricte que s'est engage de respecter le CHU d'Amiens par la mise en place d'un systeme de dosimetrie operationnelle et l'application de l'arrete du 12/02/2004. (auteur)Files
48081008.pdf
Files
(710.6 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:d960ba641cf41ba1fd6f490a511fce00
|
710.6 kB | Preview Download |
Additional details
Additional titles
- Original title (French)
- Evaluation comparative de la qualite image de differents systemes de radiologie numerique et Controle qualite et optimisation de la radioprotection au Centre Hospitalier Universitaire d'Amiens
Identifiers
Publishing Information
- Imprint Pagination
- 70 p.
- Report number
- FRNC-TH--9878
INIS
- Country of Publication
- France
- Country of Input or Organization
- France
- INIS RN
- 48081008
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE; S61: RADIATION PROTECTION AND DOSIMETRY; S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Resource subtype / Literary indicator
- Thesis
- Descriptors DEI
- BIOMEDICAL RADIOGRAPHY; COMPARATIVE EVALUATIONS; DIGITAL SYSTEMS; DOSIMETRY; HOSPITALS; IONIZATION CHAMBERS; LATENT IMAGES; OPTIMIZATION; PATIENTS; PHANTOMS; QUALITY CONTROL; QUANTUM EFFICIENCY; SCINTILLATOR-PHOTODIODE DETECTORS; SPATIAL RESOLUTION; SPECIFICATIONS; THERMOLUMINESCENT DOSEMETERS; TRANSFER FUNCTIONS; X-RAY TUBES
- Descriptors DEC
- BUILDINGS; CONTROL; DIAGNOSTIC TECHNIQUES; DOSEMETERS; EFFICIENCY; ELECTRON TUBES; EQUIPMENT; EVALUATION; FUNCTIONS; LUMINESCENT DOSEMETERS; MEASURING INSTRUMENTS; MEDICAL ESTABLISHMENTS; MEDICINE; MOCKUP; NUCLEAR MEDICINE; RADIATION DETECTORS; RADIOLOGY; RESOLUTION; SCINTILLATION COUNTERS; STRUCTURAL MODELS; X-RAY EQUIPMENT
Optional Information
- Notes
- 31 refs.; Available from the INIS Liaison Officer for France, see the 'INIS contacts' section of the INIS website for current contact and E-mail addresses: http://www.iaea.org/inis/Contacts/