Description

In this paper, we report the first measurement of the time-integrated spatial coherence of the Ni-like Ag X-ray laser at 13.9 nm pumped by a 1.5 ps, 20 J Nd glass laser, in which the transient collisional excitation (TCE) pumping scheme is realized. The time-integrated complex coherence factor (CCF) of the X-ray laser has been determined from partially coherent diffraction patterns of a multislit array placed 1 m away from the X-ray laser source. The transverse coherence lengths in the directions horizontal and vertical to the Ag target surface are estimated respectively to be within 110 μm to 140 μm at a position 1 m from the X-ray laser source. We tried to explain the profile of the CCF with a quasi-monochromatic incoherent source model with various profiles. (author)

Additional details

Publishing Information

Journal Title
Japanese Journal of Applied Physics. Part 1, Regular Papers, Short Notes and Review Papers
Journal Volume
42
Journal Issue
2A
Journal Page Range
p. 443-448
ISSN
0021-4922

Optional Information

Notes
26 refs, 7 figs.