A new monochromator system has been constructed which provides an energy resolution of 0.005 eV and an angular divergence of 0.4 arc seconds at an energy of 14.413 keV. In conjunction with a highly perfect crystal of isotopically enriched 57Fe2O3, a beam of nuclear resonant photons was extracted from the synchrotron continuum with signal to noise ratio of 100:1, and an intensity of >2 quanta/sec. 14 refs., 9 figs