Published 1978
| Version v1
Journal article
Heat exchangers for HHT plants
- 1. Sulzer Bros. Ltd., Winterthur (Switzerland)
- 2. Eidgenoessisches Inst. fuer Reaktorforschung, Wuerenlingen (Switzerland)
Description
Closed gas turbine installations are equipped with recuperator, precooler and, depending on the design concept, an intercooler as well. If the heat source is a nuclear reactor, core auxiliary heat interchangers must be provided additionally. The report deals with the corresponding heat exchangers of the HHT reference plant (high-temperature reactor with helium turbine). (Auth.)
Additional details
Publishing Information
- Journal Title
- Sulzer Tech. Rev.
- Journal Issue
- Spec. No. Nuclex 78
- Series
- Sulzer Tech. Rev.
- ISSN
- 0039-4912
INIS
- Country of Publication
- Switzerland
- Country of Input or Organization
- Switzerland
- INIS RN
- 10433742
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Descriptors DEI
- EFFICIENCY; GAS TURBINES; HELIUM; HTGR TYPE REACTORS; IN-SERVICE INSPECTION; IN-VESSEL HEAT EXCHANGERS; SPECIFICATIONS
- Descriptors DEC
- ELEMENTS; GAS COOLED REACTORS; GRAPHITE MODERATED REACTORS; HEAT EXCHANGERS; INSPECTION; NONMETALS; RARE GASES; REACTORS; TURBINES