Measurement of transverse attenuation lengths for paraffin, heavy concrete and iron around an external target for 12 GeV protons

  • 1. Kyoto Univ. (Japan). Faculty of Engineering
  • 2. National Lab. for High Energy Physics, Oho, Ibaraki (Japan)

Description

Measurements of transverse attenuation lengths were made above the external target at KEK 12 GeV proton synchrotron using activation detectors. Evaluated attenuation lengths for high energy neutrons in paraffin, heavy concrete and iron shields are (133 +- 16), (163 +- 7) and (188 +- 12)g/cm2, respectively. These values are discussed in relation with the inelastic mean free paths. (orig.)

Additional details

Publishing Information

Journal Title
Nucl. Instrum. Methods
Journal Volume
174
Journal Issue
1/2
Series
Nucl. Instrum. Methods.
Journal Page Range
271-276
ISSN
0029-554X