Published September 1992 | Version v1
Report Restricted

Ac loss measurement of SSC dipole magnets

Description

AC losses in full length and 1.5 m model SSC collider dipoles were successfully measured by the direct observation of energy flow into and out of magnets during a ramp cycle. The measurement was performed by using two double-integrating type digital volt meters (DVM's) for current and voltage measurement. Measurements were performed for six is m long ASST magnets and five 1.5 m long model magnets, inducting one 40 mm diameter magnet. There were large variations in the eddy current losses. Since these magnets use conductors with slight deviations in their internal structures and processing of the copper surface depending on the manufacturer, it is likely that there are differences in the contact resistance between strands. Correlation between the ramp rate dependence of the,quench current and the eddy current loss was evident

Availability note (English)

MF available from INIS under the Report Number; OSTI as DE93001950; NTIS; INIS; US Govt. Printing Office Dep.

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Additional details

Publishing Information

Imprint Pagination
5 p.
Report number
FNAL/C--92/238

Conference

Title
ICFA workshop on AC superconductivity.
Dates
23-25 Jun 1992.
Place
Tsukuba, Ibaraki (Japan).

Optional Information

Contract/Grant/Project number
Contract AC02-76CH03000
Funding organization
USDOE, Washington, DC (United States).
Secondary number(s)