Measurement of lineal-energy distributions for neutrons with tissue equivalent proportional counter
- 1. Tohoku Univ., Sendai (Japan)
- 2. National Institute of Radiological Sciences, Sendai (Japan)
Description
A shielding experiment was performed with Tissue Equivalent Proportional Counter (TEPC). The source neutrons were produced by bombarding 400-MeV/nucleon 12C ion on the 5-cm-thick Cu target at 0 degree using the Heavy Ion Medical Accelerator in Chiba (HIMAC) of National Institute of Radiological Science (NIRS), Japan. The TEPC was put just behind the shield. The lineal-energy distributions, the mean-quality factors and attenuation profiles of absorbed dose and dose equivalent behind the shield were obtained from the measured data
Additional details
Publishing Information
- Publisher
- KARP
- Imprint Place
- Taejon (Korea, Republic of)
- Imprint Title
- Proceedings of the first Asian and Oceanic Congress for Radiation Protection(AOCRP-1)
- Imprint Pagination
- [1 CD-ROM]
- Journal Page Range
- [8 p.]
Conference
- Title
- 1. Asian and Oceanic Congress for Radiation Protection(AOCRP-1)
- Dates
- 20-24 Oct 2002
- Place
- Seoul (Korea, Republic of)
INIS
- Country of Publication
- Korea, Republic of
- Country of Input or Organization
- Korea, Republic of
- INIS RN
- 36054111
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY;
- Resource subtype / Literary indicator
- Conference, Non-conventional Literature
- Descriptors DEI
- ATTENUATION; DOSE EQUIVALENTS; HEAVY ION ACCELERATORS; NEUTRONS; PROPORTIONAL COUNTERS; RADIATION DOSES; SHIELDING
- Descriptors DEC
- ACCELERATORS; BARYONS; DOSES; ELEMENTARY PARTICLES; FERMIONS; HADRONS; MEASURING INSTRUMENTS; NUCLEONS; RADIATION DETECTORS
Optional Information
- Notes
- 5 refs, 6 figs