Published January 1, 2008
| Version v1
Miscellaneous
Proton induced activation in mercury: Comparison of measurements and calculations
Creators
- 1. Oak Ridge National Laboratory, TN (United States)
Description
Measurements and simulations of the proton beam interaction with the mercury target were performed to support Spallation Neutron Source design. Due to the abundance of isotopes produced in mercury, the long delay between the irradiation and the measurements, and the self-shielding of the mercury sample, the measurements were difficult to perform and the activities of several isotopes have large uncertainties. Calculations predicted the activities of the most reliably measured isotopes within 20%/40%; however, some large discrepancies were observed for some isotopes for which the measurements were considered less reliable. Predicted dose rates were in very good agreement with the measurements.
Availability note (English)
Available from Oak Ridge National Laboratory, TN (US)Additional details
Publishing Information
- Imprint Pagination
- 8 p.
Conference
- Title
- 12th International Symposium on Reactor Dosimetry
- Dates
- 8-13 May 2005
- Place
- Gatlinburg, TN (United States)
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 43057848
- Subject category
- S07: ISOTOPES AND RADIATION SOURCES;
- Resource subtype / Literary indicator
- Conference, Non-conventional Literature
- Descriptors DEI
- ABUNDANCE; DESIGN; DOSE RATES; DOSIMETRY; IRRADIATION; MERCURY; NEUTRON SOURCES; PROTON BEAMS; PROTONS; SELF-SHIELDING; SPALLATION; TARGETS
- Descriptors DEC
- BARYONS; BEAMS; ELEMENTARY PARTICLES; ELEMENTS; FERMIONS; HADRONS; METALS; NUCLEAR REACTIONS; NUCLEON BEAMS; NUCLEONS; PARTICLE BEAMS; PARTICLE SOURCES; RADIATION SOURCES
Optional Information
- Contract/Grant/Project number
- AC05-00OR22725
- Notes
- pages 220-227
- Funding organization
- US Department of Energy (United States)