Temperature distribution measurements and modelling of a liquid-liquid-vapour spray column direct contact heat exchanger
- 1. Department of Aeronautical Engineering, Engineering Technical College- Najaf, Al-Furat Al-Awsat Technical University, 31001 Al- Najaf (Iraq)
- 2. University of Misan, Misan (Iraq)
- 3. University of Thi-Qar, College of Science, Chemistry Department, Thi-Qar (Iraq)
Description
Highlights: • Measurements and calculation of along 3-phase spray column DCHE. • Effect of and sparger configuration was examined. • decreases with , whilt increases. • increases with increasing continuous phase flow rates. • decreases with increasing dispersed phase flow rates. • increases with increasing Ja. This study investigates the temperature distribution of a liquid-liquid-vapour three-phase direct contact heat exchanger, both experimentally and theoretically. The experimental investigation was conducted using a Perspex column with an internal diameter of 10 cm and 100 cm height. Liquid pentane at its saturation temperature and warm water were used in the dispersed phase and continuous phase respectively. Various dispersed phase flow rates and continuous phase flow rates were tested using three different sparger configurations and two different nozzle diameters (1 & 1.25 mm). The results showed that the temperature of the continuous phase decreased with the height of the heat exchanger from its inlet at the top towards its outlet at the bottom. This behaviour was entirely opposite to the dispersed phase that flows counter currently with the continuous phase in the heat exchanger. For the same sparger and constant continuous phase flow rate (, the outlet temperature of the continuous phase was inversely affected by the dispersed phase flow rate ; while decreasing the nozzle numbers in the sparger led to a decrease in the outlet temperature of the continuous phase. Furthermore, the initial temperature of the continuous phase in terms of the Jakobs number () was found to have a significant positive impact on outlet temperature: the higher the , the higher the outlet temperature. The analytical model had an acceptable agreement with the experimental measurements.
Availability note (English)
Available from http://dx.doi.org/10.1016/j.applthermaleng.2018.04.128Additional details
Identifiers
- DOI
- 10.1016/j.applthermaleng.2018.04.128;
- PII
- S1359431117370205;
Publishing Information
- Journal Title
- Applied Thermal Engineering
- Journal Volume
- 139
- Journal Page Range
- p. 542-551
- ISSN
- 1359-4311
- CODEN
- ATENFT
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 54055317
- Subject category
- S42: ENGINEERING;
- Descriptors DEI
- CONFIGURATION; DIRECT CONTACT HEAT EXCHANGERS; EVAPORATORS; FLOW COUNTERS; FLOW RATE; HEAT TRANSFER; HOT WATER; NOZZLES; PENTANE; PERSPEX; SIMULATION; SPARGERS; TEMPERATURE DISTRIBUTION; VAPORS
- Descriptors DEC
- ALKANES; ENERGY TRANSFER; ESTERS; FLUIDS; GASES; HEAT EXCHANGERS; HYDROCARBONS; HYDROGEN COMPOUNDS; MATERIALS; MEASURING INSTRUMENTS; ORGANIC COMPOUNDS; ORGANIC POLYMERS; OXYGEN COMPOUNDS; PETROCHEMICALS; PETROLEUM PRODUCTS; PLASTICS; POLYACRYLATES; POLYMERS; POLYVINYLS; RADIATION DETECTORS; SYNTHETIC MATERIALS; WATER
Optional Information
- Copyright
- Copyright (c) 2018 Elsevier Ltd. All rights reserved.