Visualization of boiling in the mini-channel heat exchanger with fin
- 1. Tokyo Univ., Kashiwa, Chiba (Japan)
Description
The mini-channel heat exchanger with micrometer or millimeter scale has the advantages on the high efficiency and high-scalability. The ratio of the heat transfer surface over the volume is larger than that of normal one. Especially, the fin inside the channel may enhance the heat transfer. In this study, to develop the high-efficiency heat exchanger, the boiling phenomena inside the fin-type mini-channel heat exchanger has been investigated. The boiling inside the mini-channel has a strong effect on the channel wall. In the previous studies, the two-phase flow inside the mini-tube or mini-channel has been analyzed with thermography and video cameras. In this study, the boiling characteristics inside the millimeter scale channel has been visualized by the high-speed camera to evaluate the efficiency of the mini-channel. (author)
Availability note (English)
Available from Japan Society of Mechanical Engineers, 35 Shinanomachi, Shinjuku-ku, Tokyo 160-0016, JapanAdditional details
Publishing Information
- Publisher
- Japan Society of Mechanical Engineers
- Imprint Place
- Tokyo (Japan)
- Imprint Title
- Proceedings of the ICONE-15 (Revised). The 15th international conference on nuclear engineering
- Imprint Pagination
- [3174 p.]
- Journal Page Range
- [6 p.]
Conference
- Title
- 15. international conference on nuclear engineering
- Acronym
- ICONE-15
- Dates
- 22-26 Apr 2007
- Place
- Nagoya (Japan)
INIS
- Country of Publication
- Japan
- Country of Input or Organization
- Japan
- INIS RN
- 39076000
- Subject category
- S42: ENGINEERING;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- BOILING; BUBBLES; CAMERAS; FINS; FLOW VISUALIZATION; HEAT EXCHANGERS; HEAT TRANSFER; IMAGE PROCESSING; MINIATURIZATION; THERMAL EFFICIENCY; TWO-PHASE FLOW
- Descriptors DEC
- EFFICIENCY; ENERGY TRANSFER; FLUID FLOW; PHASE TRANSFORMATIONS; PROCESSING
Optional Information
- Notes
- This CD-ROM can be used for WINDOWS 9x/NT/2000/ME/XP, MACINTOSH; Acrobat Reader is included; Data in PDF format, Folder Name Final Paper, PaperID ICONE15-10630.pdf; 2 refs., 6 figs., 1 tab.