Published September 2014 | Version v1
Journal article

Effect of automatic exposure control marker with chest radiography in radiation reduction

  • 1. Severance Hospital, Yonsei University College of Medicine, Seoul (Korea, Republic of)
  • 2. LISTEM, Woonju (Korea, Republic of)
  • 3. Dept. of Biomedical Engineering, Konyang University, Nonsan (Korea, Republic of)

Description

This study focused on effects of patient exposure dose reduction with AEC (Auto Exposure Control) marker that is designed for showing location of AEC in X-ray Chest radiography. It included 880 adults who have to use Chest X-ray Digital Radiography system (DRS, LISTEM, Korea). AEC (Ion chambers are posited in top of both sides) are used to every adult and set X-ray system as Field size 17 x 17 inch, 120 kVp, FFD 180 cm. 440 people of control group are posited on detector to include both sides of lung field and the other 440 people of experimental group are set to contact their lung directly to Ion chamber (making marker to shows location). Then, measured every DAP and, estimated patient effective dose by using PCXMC 2.0. The average age of control group (M:F=245:195) is 53.9 and the average BMI is 23.4. BMI ranges from under weight: 35, normal range: 279, over weight: 106 to obese: 20 and average DAP is 223.56 mGycm2, Mean effective dose is 0.045 mSv. The average age of experimental group (M:F=197:243) is 53.7 and the average BMI is 22.7. BMI ranges from under weight: 34, normal range: 315, over weight: 85 to obese: 6 and average DAP is 207.36 mGycm2, Mean effective dose is 0.041 mSv. Experimental group shows less Mean effective dose as 0.004mSv (9.7%) than control group. Also, patient numbers who got over exposure more than 0.056 mSv (limit point to know efficiency of AEC marker) is 65 in control group(14.7%), 19 in experimental group (4.3%) and take statistics with t-Test. The statistical difference between two groups is 0.006. In order to use proper amount of X-ray in auto exposure controlled chest X-ray system, matching location between ion chamber and body part is needed, and using AEC marker (designed for showing location of ion chamber) is a way to reduce unnecessary patient exposure dose

Additional details

Publishing Information

Journal Title
Journal of the Korean Society of Radiological Technology
Journal Volume
37
Journal Issue
3
Series
6 refs, 6 figs, 8 tabs
Journal Page Range
p. 177-185
ISSN
1226-2854

INIS

Country of Publication
Korea, Republic of
Country of Input or Organization
Korea, Republic of
INIS RN
46110774
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
CHEST; CONTROL; LUNGS; PATIENTS; RADIATION DOSES; REDUCTION
Descriptors DEC
BODY; CHEMICAL REACTIONS; DOSES; ORGANS; RESPIRATORY SYSTEM