Hydrogen permeation of Inconel 625
Description
The hydrogen permeability of Inconel 625 was measured over a range of temperatures and hydrogen pressures that included values relevant to the Doublet III experiment (Inconel 625 is being used as the vacuum vessel material for Doublet III). The permeation rate obeyed a half-power dependence on hydrogen pressure down to the lowest pressure studies (10-1 Pa). The activation energy and permeation coefficient were in good agreement with published data for other Inconel-type alloys. These results will also be useful as a standard for comparison of the effectiveness of permeation barrier methods applied to path B alloys
Files
Additional details
Publishing Information
- Imprint Title
- Alloy development for irradiation performance. Quarterly progress report, January--March, 1978
- Journal Page Range
- p. 221-224.
- Report number
- DOE/ET--0058-1
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 10439237
- Subject category
- S70: PLASMA PHYSICS AND FUSION TECHNOLOGY; S36: MATERIALS SCIENCE;
- Descriptors DEI
- DIFFUSION; DOUBLET-3 DEVICE; HYDROGEN; INCONEL 625; PERMEABILITY; THERMONUCLEAR REACTORS
- Descriptors DEC
- ALLOYS; CHROMIUM ALLOYS; CLOSED PLASMA DEVICES; ELEMENTS; INCONEL ALLOYS; IRON ALLOYS; MOLYBDENUM ALLOYS; NICKEL ALLOYS; NICKEL BASE ALLOYS; NIOBIUM ALLOYS; NONMETALS; TANTALUM ALLOYS; THERMONUCLEAR DEVICES; TOKAMAK DEVICES; TRANSITION ELEMENT ALLOYS