The out of order an equipment is ordinary natural process happened, above all the equipment be used continually with very old time, as for as out of order can be resulted from kinds of cause. Lift motor out of order can be result by motor is broken or happened the body shorten then affected do not function it the lift, so until done rewinding process. The rewinding is furl to repeat at motor coils. Motor of Lift represent main activator machine turning around shares pulley. Lift Motor will work if there is called in normal operation condition or the moment manual switch if done maintenance. Motor used at lift is motor three phases with two speeds that is low speed and high speed. Rewinding process must be done removed the motor from Lift machine and have to be done by professional workshop. In during function test take place, temperature at coil reach 70oC (exceeding boundary permitted). After done installation addition thermal at motor coil hence his temperature become normal that is only reach 50 oC. (author)

Additional details

Additional titles

Original title (Indonesian)
Analisis Unjuk Kerja Motor Lift RSG-GAS Setelah Dilakukan Perbaikan

Publishing Information

Journal Title
Buletin Pengelolaan Reaktor Nuklir
Journal Volume
3
Journal Issue
1
Journal Page Range
p. 66-76
ISSN
0216-2695

Optional Information

Notes
3 refs; 3 tabs; 8 figs