Published May 2001 | Version v1
Miscellaneous

Installation of BNCT irradiation facility and measurement of neutron and gamma-ray leakages

  • 1. KAERI, Taejon (Korea, Republic of)

Description

The irradiation facility for BNCT was installed at the IR beam tube of HANARO, and the leakages of neutron and gamma-ray were measured. The safety in the installation work was ensued by using the special jigs with the working procedure verified through the pre-exercises. The lead gasket containing a small amount of antimony was developed and used for He sealing in the IR beam tube. When the water shutter was closed, the neutron leakage was negligible, and the maximum dose rate of gamma-ray at the 10 MW of reactor power was 12 mSv/hr. The geometry of front shielding was determined by using this measurement result

Part of:
Proceedings of the Korean Nuclear Society spring meeting

Additional details

Publishing Information

Publisher
KNS
Imprint Place
Taejon (Korea, Republic of)
Imprint Title
Proceedings of the Korean Nuclear Society spring meeting
Imprint Pagination
[ONE CDROM]
Journal Page Range
[8 p.]

Conference

Title
2001 spring meeting of the Korean Nuclear Society
Dates
24-25 May 2001
Place
Cheju (Korea, Republic of)

Optional Information

Notes
4 refs, 6 figs, 1 tab