Published June 1, 1992 | Version v1
Journal article

Analogous filters for beam shaping in diagnostic radiology

  • 1. Notre-Dame Hospital, Montreal, PQ (Canada). Dept. of Biomedical Physics

Description

A computer simulation based on photon transport calculation was used to evaluate the properties of a wide variety of materials that could be used for the filtration of x-ray beams. A single filter was added to the inherent filtration. For comparison, the concept of analogous filters was introduced: two filters were considered analogous if both produced the same ratio of entrance exposure at the patient to the energy absorbed in the detector consisting of a pair of intensifying screens positioned immediately behind the water phantom. The efficiency, contrast and integral dose were calculated for filters of odd atomic numbers from 1 to 91 with a large number of different parameters (48,600 different combinations). They include essentially all major diagnostic radiology procedures, except mammography. Only extreme cases are presented here. (Author)

Additional details

Publishing Information

Journal Title
Physics in Medicine and Biology
Journal Volume
37
Journal Issue
6
Series
Phys. Med. Biol.
Journal Page Range
1313-1320
ISSN
0031-9155
CODEN
PHMBA

INIS

Country of Publication
United Kingdom
Country of Input or Organization
United Kingdom
INIS RN
23079005
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
ATTENUATION; BEAM SHAPING; COMPUTERIZED SIMULATION; DIAGNOSTIC TECHNIQUES; PHOTON BEAMS; PHOTON TRANSPORT
Descriptors DEC
BEAMS; NEUTRAL-PARTICLE TRANSPORT; RADIATION TRANSPORT; SIMULATION