Published October 2004
| Version v1
Journal article
The Evaluation of Surface Crack in Paramagnetic Material by FEF Technique
Description
FEF(Focused Electromagnetic Field) technique was newly developed that is based on the induction principle exciting electromagnetic field. The technique consists of an induction wire and a sensor for detecting electromagnetic field, and is applied in a non-contact mode. In this study, the technique was applied to the evaluation of EDM slits in some conductive materials - aluminum alloy, stainless steel and Inconel alloy. The voltage in the non-defect region is depended upon the measurement lift-off. The voltage signals on defects are measured with peak values, and the peak values changed with the depth of defects. The voltage distributions for all conductive materials are the same trend
Additional details
Publishing Information
- Journal Title
- Journal of the Korean Society for Nondestructive Testing
- Journal Volume
- 24
- Journal Issue
- 5
- Series
- 6 refs, 7 figs
- Journal Page Range
- p. 532-537
- ISSN
- 1225-7842
INIS
- Country of Publication
- Korea, Republic of
- Country of Input or Organization
- Korea, Republic of
- INIS RN
- 42048839
- Subject category
- S42: ENGINEERING; S36: MATERIALS SCIENCE;
- Descriptors DEI
- CRACKS; DEFECTS; ELECTROMAGNETIC FIELDS; EVALUATION; SENSORS