High-resolution phase-contrast MRI of aortic and pulmonary blood flow during rest and physical exercise using a MRI compatible bicycle ergometer
Creators
- 1. Department of Radiology, German Cancer Research Center, INF 280, 69120 Heidelberg (Germany)
- 2. Department of Diagnostic and Interventional Radiology, University Medical Center Heidelberg, INF 110, 69120 Heidelberg (Germany)
- 3. Department of Biostatistics, German Cancer Research Center, INF 280, 69120 Heidelberg (Germany)
- 4. Department of Pediatric Radiology, University Medical Center Heidelberg, INF 430, 69120 Heidelberg (Germany)
Description
Purpose: To establish high-resolution phase-contrast magnetic resonance imaging (PC-MRI) using a MRI compatible bicycle ergometer to quantify aortic and pulmonary blood flow during resting conditions and exercise. Materials and methods: In 20 healthy volunteers (mean age, 26.8 ± 5.0 years) high-resolution PC-MRI (mean temporal resolution, 7.4 ± 3.2 ms) was performed in the ascending aorta (AA) and main pulmonary artery (PA) during physical rest and three exercise stages: stage 1, no-load operation; stage 2, heart rate increase 40% compared to rest; stage 3, heart rate increase 80% compared to rest. Flow quantification in AA and PA included flow volume (FV), average velocity (AV), peak velocity (PV) and time to PV (TP). Results: In stage 1 only TP demonstrated a significant change. With progression to stage 2, all parameters altered significantly. Flow measurements during stage 3 evidenced further alterations only of AV and TP regarding both AA and PA. The deviation of the heart rate from the desired target value was significantly higher for stage 3 compared to stage 2, and 15% of the subjects did not reach the desired target heart rate of stage 3 at all. Conclusion: Flow quantification by high-resolution PC-MRI during exercise using a MRI compatible bicycle ergometer is feasible. Medium exercise stages are necessary and sufficient to demonstrate flow alterations in healthy volunteers. PC-MRI ergometry may give insights into aberrant hemodynamic conditions in patients with cardiovascular and pulmonary disease.
Availability note (English)
Available from http://dx.doi.org/10.1016/j.ejrad.2010.06.045Additional details
Identifiers
- DOI
- 10.1016/j.ejrad.2010.06.045;
- PII
- S0720-048X(10)00321-9;
Publishing Information
- Journal Title
- European Journal of Radiology
- Journal Volume
- 80
- Journal Issue
- 1
- Journal Page Range
- p. 103-108
- ISSN
- 0720-048X
- CODEN
- EJRADR
INIS
- Country of Publication
- Netherlands
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 43065192
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- AORTA; BLOOD FLOW; DISEASES; HEART; MATERIALS; NMR IMAGING; PATIENTS; RESOLUTION
- Descriptors DEC
- ARTERIES; BLOOD VESSELS; BODY; CARDIOVASCULAR SYSTEM; DIAGNOSTIC TECHNIQUES; ORGANS
Optional Information
- Copyright
- Copyright (c) 2010 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.