Using half-cell potential measurement to access the severity of corrosion in reinforced concrete structures in Gentilly-2 reactor building
Creators
- 1. Gentilly-2 Nuclear Power Plant, Becancour (Canada)
- 2. LVM Technisol, Quebec, PQ (Canada)
Description
The half-cell potential technique has been used to assess the corrosion in the reactor's building ring beam of the Gentilly-2 nuclear power plant. It is a non-destructive technique based on the ASTM C 876 Standard. Corrosion is the result of a difference of potential between anodic and cathodic zones within the re-bars network and these potential differences are measured in the half-cell potential technique. Time exposure is the leading factor and we recommend the installation of permanent electrodes of reference in strategic areas. The results show a low corrosion activity level on 98% of the investigated surface and no severe corrosion potential reading has been registered. Furthermore the exercise shows that the repair technique has no influence on the corrosion activity of the steel network. Since most of the readings are located in the low corrosion activity level (from 0 to -100 mV), it illustrates that there is heterogeneity of the corrosion activity within the ring beam. We recommend a system to monitor the evolution of the corrosion phenomena in real time. The installation of reference electrodes positioned in some ring beam strategic areas is a simple and accurate way of monitoring the corrosion activity of the steel in the structure. In the case where an evolution in higher level is noted in the corrosion activity, it would be possible to act and prevent any further degradation of the structure
Additional details
Publishing Information
- Imprint Title
- Ageing Management of Thick-Walled Concrete Structures, Including ISI, Maintenance and Repair, Instrumentation Methods and Safety Assessment in View of LTO. Workshop Proceedings
- Imprint Pagination
- 721 p.
- Journal Page Range
- p. 313-329
- Report number
- NEA-CSNI-R--2009-9
Conference
- Title
- Workshop on Ageing Management of Thick-Walled Concrete Structures, Including ISI, Maintenance and Repair, Instrumentation Methods and Safety Assessment in View of LTO
- Dates
- 1-3 Oct 2008
- Place
- Prague (Czech Republic)
INIS
- Country of Publication
- Nuclear Energy Agency of the OECD (NEA)
- Country of Input or Organization
- Nuclear Energy Agency of the OECD (NEA)
- INIS RN
- 49016078
- Subject category
- S42: ENGINEERING; S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS; S36: MATERIALS SCIENCE;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- CATHODIC PROTECTION; CONTAINMENT BUILDINGS; CORROSION RESISTANCE; ELECTRICAL TESTING; ELECTROCHEMICAL CORROSION; ELECTRODES; GENTILLY-2 REACTOR; REAL TIME SYSTEMS; REINFORCED CONCRETE; STEELS
- Descriptors DEC
- ALLOYS; BUILDING MATERIALS; BUILDINGS; CANDU TYPE REACTORS; CARBON ADDITIONS; CHEMICAL REACTIONS; COMPOSITE MATERIALS; CONCRETES; CONTAINMENT; CORROSION; CORROSION PROTECTION; HEAVY WATER COOLED REACTORS; HEAVY WATER MODERATED REACTORS; IRON ALLOYS; IRON BASE ALLOYS; MATERIALS; MATERIALS TESTING; NATURAL URANIUM REACTORS; NONDESTRUCTIVE TESTING; PHWR TYPE REACTORS; POWER REACTORS; PRESSURE TUBE REACTORS; REACTORS; REINFORCED MATERIALS; TESTING; THERMAL REACTORS; TRANSITION ELEMENT ALLOYS