Published January 2010 | Version v1
Journal article

Ion source plasma parameters measurement based on Langmuir probe with commercial frequency sweep

  • 1. Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China)

Description

Langmuir probe is one of the main diagnostic tools to measure the plasma parameters in the ion source. In this article, the commercial frequency power, which is sine wave of 50 Hz, was supplied on the Langmuir probe to measure the plasma parameters. The best feature of this probe sweep voltage is that it does not need extra design. The probe I-V characteristic curve can be got in less than 5 ms and the plasma parameters, the electron temperature and the electron density, varying with the time can be got in one plasma discharge of 400 ms.

Availability note (English)

Available from http://dx.doi.org/10.1016/j.fusengdes.2009.06.004

Additional details

Identifiers

DOI
10.1016/j.fusengdes.2009.06.004;
PII
S0920-3796(09)00249-X;

Publishing Information

Journal Title
Fusion Engineering and Design
Journal Volume
85
Journal Issue
1
Journal Page Range
p. 64-68
ISSN
0920-3796
CODEN
FEDEEE

INIS

Country of Publication
Netherlands
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
41069269
Subject category
S70: PLASMA PHYSICS AND FUSION TECHNOLOGY;
Descriptors DEI
ELECTRIC CONDUCTIVITY; ELECTRON DENSITY; ELECTRON TEMPERATURE; ION SOURCES; LANGMUIR PROBE; PLASMA DIAGNOSTICS
Descriptors DEC
ELECTRIC PROBES; ELECTRICAL PROPERTIES; PHYSICAL PROPERTIES; PROBES

Optional Information

Copyright