Published December 2013 | Version v1
Journal article

Research on 2D ray effect elimination module of radiation shielding code ARES

  • 1. School of Nuclear Science and Engineering, North China Electric Power University, Beijing (China)

Description

In the analysis of radiation shielding calculation, discrete ordinate method (SN method) is one of the main international calculation methods currently. SN method will produce ray effect while solving the transport equation along only a few specific directions, especially for isolated point sources, large volume of void regions and strongly absorbing media, ray effect is very obvious. Based on first collision source method, the uncollided neutron flux was solved by semi-analytic method and then first collision source term was calculated, the contributions of the isolated point source to all spatial grids were equivalent to the sum of that of each grid's first collision source, thus ray effect could be remedied. 2D ray effect elimination module ARESRayEffect2D was developed. ARESRayEffect2D was coupled with 2D discrete ordinate transport module ARES2D, and compared with the advanced shielding calculation programs for a series of models. The results demonstrate that ray effect can be effectively mitigated. (authors)

Additional details

Publishing Information

Journal Title
Atomic Energy Science and Technology
Journal Volume
47
Journal Issue
suppl
Journal Page Range
p. 700-706
ISSN
1000-6931

Optional Information

Notes
8 figs., 2 tabs., 8 refs.